Banda de tensão intramedular com parafusos em fraturas do colo do úmero em duas e três partes

“sistema pára-quedas"

Authors

  • Eduardo Libório Menniti Hospital do Servidor Público Estadual
  • Rômulo Brasil Filho Hospital do Servidor Público Estadual
  • Cantídio Salvador Filardi Filho Hospital do Servidor Público Estadual
  • Marcus Vinícius Baptista Hospital do Servidor Público Estadual
  • Samir Salim Daher Hospital do Servidor Público Estadual

Keywords:

Humeral fractures, Fracture fixation

Abstract

Technique for fixation of two and three part proximal humeral fracture , tension band with one or two screws , “parachuting system”. The authors introduce a new technique for surgical treatment of two and three part proximal humeral fractures. This method consists of an intramedullary tension band , linking the proximal fragments of the fracture to the umeral shaft with two ethibond threads nº 5 , and one or two maleolar screws, producing a stable synthesis with litlle injury to the soft tissues and the advantages that it does not be removed. The final shape of the synthesis resambles an open parachute.

Downloads

Download data is not yet available.

Author Biographies

Eduardo Libório Menniti, Hospital do Servidor Público Estadual

Membro do Grupo do Ombro e Cotovelo do Serviço de Ortopedia e Traumatologia do Hospital do Servidor Público Estadual - IAMSPE - São Paulo - SP.

Rômulo Brasil Filho, Hospital do Servidor Público Estadual

Membro do Grupo do Ombro e Cotovelo do Serviço de Ortopedia e Traumatologia do Hospital do Servidor Público Estadual - IAMSPE - São Paulo - SP.

Cantídio Salvador Filardi Filho, Hospital do Servidor Público Estadual

Membro do Grupo do Ombro e Cotovelo do Serviço de Ortopedia e Traumatologia do Hospital do Servidor Público Estadual - IAMSPE - São Paulo - SP.

Marcus Vinícius Baptista, Hospital do Servidor Público Estadual

Membros do Grupo do Ombro e Cotovelo do Serviço de Ortopedia e Traumatologia do Hospital do Servidor Público Estadual - IAMSPE - São Paulo - SP.

Samir Salim Daher, Hospital do Servidor Público Estadual

Membro do Grupo do Ombro e Cotovelo do Serviço de Ortopedia e Traumatologia do Hospital do Servidor Público Estadual - IAMSPE - São Paulo - SP.

References

Menniti EL, Brasil Filho R, Filardi Filho CS, Baptista MV, Daher SS. Banda de tensão intramedular com parafusos em fraturas do colo do úmero em duas e três partes: “ Sistema pára-quedas “. Rev Bras Ortop - 1997;32:713-7.

Menniti EL, Brasil Filho R, Filardi Filho CS, Baptista MV, Daher SS. Original technique for fixation of two and three part proximal humerus fracture , tension band with two screws - parachunting system.- Poster presentetion - 10TH Congress of European Society for the

Shoulder and Elbow .- Salburg , 15-17 September 1997

Bibliani LU. Fractures of the proximal humerus. In: Rockwood CA Jr, Matsen III FA. The shoulder. Philadelfia:Saunders; 1990. p.278-334.

Norris T. Fractures of the proximal humerus and dislocaton of the shoulder. In: Brower BD, Jupiter JB Levine AM et al. Skeletal trauma:fractures, dislocations, ligamentous injuries. Philadelphia: Saunders; 1992. p.1201-90.

Young TB, Wallace WA. Conservative treatment of fractures and fracture-dislocations of the upper end of the humerus.J Bone Joint Surg (B) 1985; 67:373-7.

Neer CS 2d. Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg (A) 1970;52:1077-89.

Koval KJ, Blair B, Takei R, Kummer FJ, Zuckerman JD. Surgical neck fractures of the proximal humerus: a laboratory evaluation of ten fixation techniques. J Trauma 1996;40:778-83.

Paavolainen P, Bajrkenheim JM, Slatis P, Paukku P. Operative treatment of severe proximal humeral fractures. Acta Orthop Scand 1983;54:374-9.

Robinson CM, Christie J. The two-part proximal humeral fracture: a review of operative treatment using two techniques. Injury 1993;24:123-5.

Published

2001-01-24

How to Cite

1.
Menniti EL, Brasil Filho R, Filardi Filho CS, Baptista MV, Daher SS. Banda de tensão intramedular com parafusos em fraturas do colo do úmero em duas e três partes: “sistema pára-quedas". RTO [Internet]. 2001 Jan. 24 [cited 2025 Jun. 22];1(1):7-12. Available from: https://www.tecnicasemortopedia.com.br/revista/article/view/3